Problem & Solution
Power Electronics Add-on PEA: Error 1003 Occurred at Open VI reference

Problem: While trying to load the PEA circuit model in Veristand the following error shows: 

Error 1003 Occurred at Open VI reference


 This error has been reported for Veristand versions 2024Q3 in conjunction with early (Beta)1.5.x.x.  versions of the PEA. 


Solution

The cause of the error is a known issue in the LabVIEW Runtime Engine 2024 Q3 (24.3.0.49385-0+f233)


https://www.ni.com/en/support/documentation/bugs/24/labview-2024-q3-known-issues.html#:~:text=Jul%2017%2C%202024-,2798144,-MATLAB%20Script%20Nodes


Known Issue number is 2798144: MATLAB "Script Nodes Break VIs"


The issue is resolved by installing Patch 1 of the LabVIEW Runtime Engine 2024 Q3