Reference Number: AA-02345// Views: AA-02345// Created: 2024-08-14 13:20:57// Last Updated: 2024-08-19 14:07:23 Problem & Solution Power Electronics Add-on PEA: Error 1003 Occurred at Open VI reference Problem: While trying to load the PEA circuit model in Veristand the following error shows: Error 1003 Occurred at Open VI reference This error has been reported for Veristand versions 2024Q3 in conjunction with early (Beta)1.5.x.x. versions of the PEA. Solution: The cause of the error is a known issue in the LabVIEW Runtime Engine 2024 Q3 (24.3.0.49385-0+f233) https://www.ni.com/en/support/documentation/bugs/24/labview-2024-q3-known-issues.html#:~:text=Jul%2017%2C%202024-,2798144,-MATLAB%20Script%20Nodes Known Issue number is 2798144: MATLAB "Script Nodes Break VIs" The issue is resolved by installing Patch 1 of the LabVIEW Runtime Engine 2024 Q3 |