Knowledge Base
Welcome to OPAL-RT’s Knowledge Base
OPAL-RT offers a repository of support information for optimal use of its technology.
Please note that OPAL-RT knowledge base is not fully optimized for mobile platforms.
For optimal experience, use a desktop computer.
Reference Number: AA-02323// Views: AA-02323// Created: 2024-06-25 17:38:38// Last Updated: 2024-06-25 17:41:43 Problem & Solution Power Electronics , CMDE Add-On for VeriStand error -2202 The specified name does not exist. NI-PEA / CMDE error -2202 The specified name does not exist Problem:The error appears when the target name (FPGA name) in the PEA/CMDE main page does not match the name in the NI -Max explorer. Double check that both these names are the same, otherwise the PEA/CMDE custom device cannot be properly linked to the actual NI controller device: for the image below, the target name on the PEA main page is "FPGA0" and so it is the name of the PXI-7868R FPGA on the NI-MAX interface |