Problem & Solution
Power Electronics , CMDE Add-On for VeriStand error -2202 The specified name does not exist.

NI-PEA / CMDE error -2202 The specified name does not exist

Problem:The error  appears when the target name (FPGA name) in the  PEA/CMDE main page does not match the name in the NI -Max explorer.


 Double check that both these names are the same, otherwise the PEA/CMDE custom device cannot be properly linked to the actual NI controller device: for the image below, the target name on the PEA main page is "FPGA0" and so it is the name of the PXI-7868R FPGA on the NI-MAX interface